| Type: | |
|---|---|
| spare parts avaliable: | |
| Availability: | |
| Quantity: | |
PVM
Xeriwell or Others
The Eaton Vickers PVM series hydraulic pumps are highly efficient variable displacement piston pumps designed for open-circuit systems. With advanced engineering, these pumps offer precision, reliability, and low-noise performance, making them ideal for industrial applications such as manufacturing and processing equipment.
Features:
1)Wide Operating Range: The PVM series supports pressures up to 315 bar (continuous) and 350 bar (peak), ensuring dependable performance in high-demand operations.
2)Quiet Operation: Optimized designs significantly reduce noise levels, providing a quieter work environment and improved system efficiency.
3)Energy Efficiency: The variable displacement mechanism adjusts flow rates as needed, reducing energy consumption and operational costs.
4)Compact and Durable: Lightweight construction and robust materials ensure durability while maintaining a compact design suitable for confined spaces.
5)Flexible Configuration: With multiple displacement options and control settings, including high-speed and low-noise versions, the PVM pumps can be customized for specific system requirements.
The Eaton Vickers PVM series combines reliability and adaptability, making it a trusted choice for industries requiring efficient and precise hydraulic solutions.
Type: PVM018, PVM020, PVM045, PVM050, PVM057, PVM063, PVM074, PVM081, PVM098, PVM106, PVM131, PVM141
EATON PVM 018/020/045/050/057/063/074/081/098/106/131/141 Hydraulic Pump spare parts list:
| Displacement,Pressure and Flow Ratings At 50°C (120°F),SAE 10W oil,1 bar absolute (0 psig) inlet | ||||||||
| Model Series | Maximum Geometric Displacement cm/r (in/r) | Maximum Pressure bar (psi) | Maximum Flow at 210 bar (3000 psi) l/min (USgpm) |
|||||
| Continuous | Intermittent* | Peak** | @ 1800 r/min | @ 1500 r/min | @ 1200 r/min | @ 1000 r/min | ||
| PVM018 | 18 (1.1) | 280 (4000) | 320 (4600) | 350 (5000) | 31 (8.2) | 26 (7) | 21 (5.5) | 17 (4.5) |
| PVM020 | 21,1 (1.29) | 230 (3300) | 250 (3600) | 280 (4000) | 35 (9) | 29 (8) | 23 (6) | 19 (5) |
| PVM045 | 45,1 (2.75) | 280 (4000) | 320 (4600) | 350 (5000) | 76 (20) | 65 (17) | 49 (13) | 42 (11) |
| PVM050 | 50,0 (3.05) | 230 (3300) | 250 (3600) | 280 (4000) | 87 (23) | 75 (20) | 62 (16) | 49 (13) |
| PVM057 | 57,4 (3.50) | 280 (4000) | 320 (4600) | 350 (5000) | 102 (27) | 85 (22.4) | 66 (17.4) | 54 (14.3) |
| PVM063 | 63,1 (3.85) | 230 (3300) | 250 (3600) | 280 (4000) | 111 (29) | 93 (24) | 74 (19) | 60 (16) |
| PVM074 | 73,7 (4.50) | 280 (4000) | 320 (4600) | 350 (5000) | 127 (33.5) | 106 (28) | 86 (22.7) | 70 (18.5) |
| PVM081 | 81,0 (4.94) | 230 (3300) | 250 (3600) | 280 (4000) | 139 (37) | 116 (31) | 93 (25) | 76 (20) |
| PVM098 | 98,3 (6.00) | 280 (4000) | 320 (4600) | 350 (5000) | 170 (45) | 141 (37) | 112 (29.6) | 92 (24.3) |
| PVM106 | 106,5 (6.50) | 230 (3300) | 250 (3600) | 280 (4000) | 187 (49) | 155 (41) | 123 (32) | 102 (27) |
| PVM131 | 131,1 (8.00) | 280 (4000) | 320 (4600) | 350 (5000) | 215 (57) | 178 (47) | 141 (37) | 118 (31) |
| PVM141 | 141,0 (8.60) | 230 (3300) | 250 (3600) | 280 (4000) | 238 (63) | 199 (53) | 158 (42) | 131 (35) |
| *Less than 10% of duty cycle. **Momentary system pressure spikes only. |
||||||||
| Speed,Input Power and Torque Ratings At 50°C (120°F),SAE 10W oil,1 bar absolute (0 psig) inlet | |||||||
| Model Series | Maximum Operating Speed r/min | Maximum Input Power at 210 bar (3000 psi) kw (hp) | Maximum Torque at 210 bar (3000 psi) Nm (lb·ft) | Approximate Weight kg (lb) | |||
| @ 1800 r/min | @ 1500 r/min | @ 1200 r/min | @ 1000 r/min | ||||
| PVM018 | 1800 | 16 (22) | 13 (18) | 11 (15) | 9 (12) | 84 (62) | 15 (33) |
| PVM020 | 1800 | 14 (18) | 11 (15) | 9 (12) | 8 (10) | 73 (54) | 15 (33) |
| PVM045 | 1800 | 41 (55) | 34 (46) | 27 (37) | 23 (31) | 221 (163) | 24 (52) |
| PVM050 | 1800 | 35 (47) | 30 (40) | 28 (38) | 23 (31) | 190 (140) | 24 (52) |
| PVM057 | 1800 | 52 (70) | 44 (59) | 36 (49) | 29 (39) | 272 (201) | 36 (79) |
| PVM063 | 1800 | 42 (57) | 36 (48) | 29 (39) | 24 (32) | 228 (168) | 36 (79) |
| PVM074 | 1800 | 63 (84) | 52 (70) | 42 (56) | 35 (47) | 334 (246) | 45 (99) |
| PVM081 | 1800 | 56 (75) | 46 (62) | 35 (47) | 28 (37) | 286 (211) | 45 (99) |
| PVM098 | 1800 | 88 (118) | 72 (97) | 58 (78) | 48 (64) | 464 (342) | 55 (121) |
| PVM106 | 1800 | 72 (97) | 60 (80) | 48 (64) | 40 (54) | 383 (282) | 55 (121) |
| PVM131 | 1800 | 113 (152) | 94 (126) | 75 (101) | 63 (85) | 596 (440) | 66 (145) |
| PVM141 | 1800 | 94 (126) | 79 (106) | 63 (85) | 53 (71) | 497 (367) | 66 (145) |
| Standard Response Times* | ||
| Model Series | On Stroke (msec)Off Stroke (msec) | |
| PVM018 | 30 | 25 |
| PVM020 | 39 | 26 |
| PVM045 | 140 | 40 |
| PVM050 | 140 | 40 |
| PVM057 | 65 | 20 |
| PVM063 | 85 | 20 |
| Standard Response Times* | ||
| Model Series | On Stroke (msec)Off Stroke (msec) | |
| PVM074 | 85 | 30 |
| PVM081 | 85 | 30 |
| PVM098 | 65 | 25 |
| PVM106 | 72 | 29 |
| PVM131 | 135 | 30 |
| PVM141 | 100 | 30 |
| *Values with pressure compensator control. | ||